High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain
Published on: May 10, 2012
BOLD contrast and noise characteristics of densely sampled multi-echo fMRI data
1Department of Medical Biophysics, University of Toronto, Toronto, M5G 2M9 ON, Canada. mchiew@rotman-baycrest.on.ca
Abstract:
Blood oxygenation level dependent (BOLD) contrast in functional magnetic resonance imaging (fMRI) can be enhanced using multi-echo imaging and postprocessing techniques that combine the echoes in weighted summation. Here, existing echo-weighting methods are reassessed in the context of an explicit physiological noise model, and a new method is introduced: weights that scale linearly with echo time. Additionally, a method using data-driven weights defined using principal component analysis (PCA) is included for comparison. Differences in BOLD contrast enhancement between methods were compared analytically where possible, and using Monte Carlo simulations for different noise conditions and different combinations of acquisition parameters. The comparisons were also validated through densely sampled (256-echo) multi-echo fMRI experimental data acquired at 1.5T and 3.0T. Results indicated that the contrast-to-noise ratio (CNR) of the studied weighting methods have a strong dependence on the physiological noise, echo spacing and the width of the sampling window. With low noise correlations between echoes, contrast gain for all weighting methods was shown to have a square root dependence on the echo sampling density, and in typical experimental noise conditions, increasing the sampling window beyond 3·T2* produced marginal additional benefit. Simulations and experiments also emphasized that noise correlations between echoes are likely the main factor limiting the potential CNR gains achievable by densely sampled multi-echo fMRI.
More Related Videos
11:00Reliable Acquisition of Electroencephalography Data during Simultaneous Electroencephalography and Functional MRI
Published on: March 19, 2021
08:33A Randomized, Sham-Controlled Trial of Cranial Electrical Stimulation for Fibromyalgia Pain and Physical Function, Using Brain Imaging Biomarkers
Published on: January 5, 2024
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
Magnetic Resonance Imaging
¹H NMR Signal Multiplicity: Splitting Patterns