Radiation dose at coronary CT angiography: second-generation dual-source CT versus single-source 64-MDCT and
Christian Fink1, Radko Krissak, Thomas Henzler
1Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. christian.fink@umm.de
Objective:
The purpose of this study was to assess the radiation doses of different coronary CTA (CTA) protocols: second-generation dual-source 128-MDCT, first-generation dual-source 64-MDCT, and single-source 64-MDCT.
Materials And Methods:
Thermoluminescent dosimetry was used to determine scanner-specific dose coefficients for standard coronary CTA of an anthropomorphic phantom. These coefficients were used to estimate the effective doses (EDs) of retrospectively gated, prospectively triggered, and prospectively triggered high pitch coronary CTA performed at 100 and 120 kV. The coronary CTA protocols used in imaging of 43 patients undergoing dual-source 128-MDCT were analyzed for ED, image quality, and signal-to-noise ratio.
Results:
Regardless of coronary CTA protocol and CT system, imaging at 100 kV lowered the ED 40-50%. In retrospectively gated 120-kV coronary CTA, the ED ranged from 5.7 to 10.7 mSv and was approximately 50% lower with single-source 64-MDCT than with either DSCT protocol. In prospectively triggered 120-kV coronary CTA, the ED ranged from 3.8 to 4.0 mSv. The lowest ED of all protocols (1.3 mSv) was observed in prospectively triggered high-pitch 100-kV coronary CTA performed with dual-source 128-MDCT. Patient measurements showed similar dose reductions for prospective triggering and low voltage settings without an influence on signal-to-noise ratio or image quality.
Conclusion:
A combination of prospective triggering with low voltage settings is an effective measure for reducing the ED of coronary CTA to values of 2-4 mSv independent of scanner system. Further dose reduction to nearly 1 mSv can be achieved with high-pitch prospectively triggered coronary CTA.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...