[Effects of different ventilation modes for one-lung ventilation anesthesia on respiratory function and F(A)/F(I)
1Department of Anesthesiology, Jinhua Central Hospital, Jinhua 321000, China. ye-cathy@126.com
Objective:
To investigate the effects of different ventilation modes for one lung ventilation anesthesia on arterial blood-gas, airway pressure, intrapulmonary shunt, and F(A)/F(I) changes in patients receiving sevoflurane inhalation.
Methods:
Thirty ASA class II-III patients with lung cancer undergoing pulmonary lobectomy were randomized into 3 equal groups. The patients in group A received volume-controlled ventilation (VCV) without positive end-expiratory pressure (PEEP) (VT=8 ml/kg, Rf=12/min), and those in group B, after a preceding VCV stabilize the airway pressure, had pressure-controlled ventilation with maintenance of an identical peak pressure (Ppeak) (Rf=12/min, PEEP=0). In group C, the patients received small tidal volume ventilation with PEEP (VT=6 ml/kg, Rf=16/min, PEEP=5 cm H(2)O). Blood gas analysis was carried out at 10 min after TLV and at 20, 45 and 70 min after one lung ventilation (OLV); the heart rate (HR), mean arterial pressure (MAP), SpO(2) and Ppeak were also recorded and blood samples collected from the artery and jugular vein at these time points. Inhalation of 1.5% sevoflurane for 20 min started at 20 min of OLV.
Results:
Compared with those in TLV, the Ppeak increased, lung compliance decreased, arterial oxygenation (PaO(2)) decreased and intrapulmonary shunt (Qs/Qt) increased during OLV. Group B showed the fastest increase of F(A)/F(I) in the initial 8 min, followed by groups A and C, but the curves became similar with the passage of time.
Conclusions:
During OLV, the 3 ventilation modes result in similar F(A)/F(I) changes during sevoflurane inhalation but PCV can increase pulmonary compliance.
More Related Videos
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Respiration
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...