Related Experiment Video
Updated: Jun 2, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Dosimetry prior to I-131-therapy of benign thyroid disease
Heribert Hänscheid1, Michael Lassmann, Christoph Reiners
1Department of Nuclear Medicine, University of Würzburg, Germany. haenscheid@nuklearmedizin.uni-wuerzburg.de
Abstract:
The activity to be administered in I-131 therapy of benign thyroid disease is determined by the radiation absorbed dose necessary to cure the disease, the target mass, and the residence time of the I-131 in the target volume. Data from 73 patients with complete sets of uptake measurements 2, 6, 24, 48, and 96 (n=53) or 120 (n=20) hours after oral administration of 1 MBq I-131 were used to deduce residence times from subsets of 3, 2, or only 1 measurement for each individual. The values were compared to those obtained with the reference method, i.e. a fit of an uptake function based on a 2-compartment model to all 5 measurements, to quantify the errors introduced by the less demanding assessments. Deviations are less than 10% if the 2- compartment uptake function is fitted to only 3 values measured after 6, 24, and 96-120h. Use of 2, 24, and 96-120h data results in errors >20% in individual patients. The effective half-lives as determined from 2 measurements after 24 and 96-120h correlate well with those deduced from the reference method with larger deviations in individuals with slow iodine kinetics and late maximal uptake. Residence times determined from the 24h uptake, assuming linear increase during the first day, and the effective half-life limited to maximum 8days underestimate the actual values systematically in patients with long and short half-lives. These errors can be eliminated by a modification of the calculation method resulting in deviations less than 14% in all but one individual for this procedure. The accuracy of methods based on only one retention value increases with the time of measurement after the administration of I-131. While systematic errors up to a factor of two occur if the 24h uptake is used for the estimate, deviations are less than 18% for measurements after 120h. The results suggest that only one late uptake assessment warrants residence time estimates with an acceptable error. Given the high inherent uncertainties in the complete dosimetry procedure, additional measurements must be considered only if a high precision of the absorbed dose assessment is required e.g. for clinical trials.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Hyperthyroidism I: Introduction
Graves Disease II: Pathophysiology
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The iodine is then...
Goiter
