Related Experiment Video
Updated: Jun 2, 2026

Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Method development for routine liquid chromatography-mass spectrometry measurement of the alcohol biomarker
Yufang Zheng1, Olof Beck, Anders Helander
1Alcohol Laboratory, Department of Laboratory Medicine, Karolinska Institutet, Stockholm, Sweden.
Background:
Phosphatidylethanol (PEth) is a group of phospholipids formed from ethanol and phosphatidylcholine by action of phospholipase D. Measurement of PEth in whole blood samples is employed as an alcohol biomarker. This work aimed to further develop an LC-MS method for PEth to make it practical for routine laboratory use.
Methods:
Blood samples were obtained from blood donors and from the clinical samples pool. A whole blood total lipid extract was separated on a C4 column, followed by ESI-MS detection of the deprotonated molecules in SIM mode or ESI-MS/MS detection of the major product ions (fatty acid fragments) by SRM.
Results:
Initial results indicated that individual calibration curves are required for MS quantitation of some PEth forms, and that deuterated analogs are preferable over phosphatidylpropanol as the internal standard. PEth-16:0/18:1 was the single most sensitive molecular form as alcohol biomarker, being detected in every of 211 blood specimens containing 0.1-20 μmol/L total PEth at reporting limits in the range 0.1-1.0 μmol/L. PEth-16:0/18:1 and 16:0/18:2, accounting for about 36% and 26%, respectively, of the total amount, correlated well with total PEth (R(2)=0.922-0.940), but the correlation was better for the sum of both forms (R(2)=0.994). Based on analysis of specimens from 200 blood donors, 95% reference intervals (CLSI C28-A3) were estimated to be <0.70 μmol/L for total PEth, <0.20 μmol/L for PEth-16:0/18:1, and <0.18 μmol/L for PEth-16:0/18:2.
Conclusions:
The LC-ESI-MS(/MS) method allowed for simultaneous qualitative and quantitative measurements of PEth forms in whole blood samples. Related to the routine application of blood PEth as alcohol biomarker, reference intervals were suggested for total PEth and the major molecular forms PEth-16:0/18:1 and 16:0/18:2.
More Related Videos
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014