Related Experiment Video
Updated: Jun 2, 2026

Using High Content Imaging to Quantify Target Engagement in Adherent Cells
Published on: November 29, 2018
Development of a plate-based assay for high-content analysis of individual untethered non-adherent cells
Chen Wang1, Lili Wang, Changqi Zhao
1Beijing Key Lab of Gene Engineering Drugs & Biological Technology, College of Life Science, Beijing Normal University, China. wangll63@yahoo.com.cn
Abstract:
Research involving non-adherent cell lines, primary cells and blood cells is definitely important, but its application in image-based assays, especially in high-content systems, is highly limited. Accordingly, efficient high-content methods to study non-adherent cells are needed not only to improve diagnostics but also for early screening of targeted drugs. A plate-based assay using adhesion reagents for multiparametric measurement with single non-adherent and non-anchored cells in a large cell population in high-content cytometry was developed and optimized. The cells preserved their identity even during extensive biomanipulations. The proposed method is highly robust for better imaging and can be used in various assays in different cellular backgrounds. Furthermore, as exemplary experiments, novel optimized assay protocols were used to study extracellular signal-regulated kinase (ERK) mitogen-activated protein kinase (MAPK) activity after cell inhibition with imatinib in chronic myelocytic leukemia K562 cells, revealing the phosphorylation kinetics of ERK MAPK. The results showed that the proposed assay detects kinase phosphorylation with good sensitivity and may be used in rapid drug screening.