Quality control technique to reduce the variability of longitudinal measurement of hemoglobin mass
C E Gough1, K Sharpe, M J Ashenden
1Department of Physiology, Australian Institute of Sport, Belconnen, Australian Capital Territory, Australia. clare.gough@ausport.gov.au
The sensitivity of the athlete blood passport to detect blood doping may be improved by the inclusion of total hemoglobin mass (Hb(mass)), but the comparability of Hb(mass) from different laboratories is unknown. To optimize detection sensitivity, the analytical variability associated with Hb(mass) measurement must be minimized. The aim of this study was to investigate the efficacy of using quality controls to minimize the variation in Hb(mass) between laboratories. Three simulated laboratories were set up in one location. Nine participants completed three carbon monoxide (CO) re-breathing tests in each laboratory. One participant completed two CO re-breathing tests in each laboratory. Simultaneously, quality controls containing Low (1-3%) and High (8-11%) concentrations of percent carboxyhemoglobin (%HbCO) were measured to compare hemoximeters in each laboratory. Linear mixed modeling was used to estimate the within-subject variation in Hb(mass), expressed as the coefficient of variation, and to estimate the effect of different laboratories. The analytic variation of Hb(mass) was 2.4% when tests were conducted in different laboratories, which reduced to 1.6% when the model accounted for between-laboratory differences. Adjustment of Hb(mass) values using quality controls achieved a comparable analytic variation of 1.7%. The majority of between-laboratory variation in Hb(mass) originated from the difference between hemoximeters, which could be eliminated using appropriate quality controls.
The sensitivity of the athlete blood passport to detect blood doping may be improved by the inclusion of total hemoglobin mass (Hb(mass)), but the comparability of Hb(mass) from different laboratories is unknown. To optimize detection sensitivity, the analytical variability associated with Hb(mass) measurement must be minimized. The aim of this study was to investigate the efficacy of using quality controls to minimize the variation in Hb(mass) between laboratories. Three simulated laboratories were set up in one location. Nine participants completed three carbon monoxide (CO) re-breathing tests in each laboratory. One participant completed two CO re-breathing tests in each laboratory. Simultaneously, quality controls containing Low (1-3%) and High (8-11%) concentrations of percent carboxyhemoglobin (%HbCO) were measured to compare hemoximeters in each laboratory. Linear mixed modeling was used to estimate the within-subject variation in Hb(mass), expressed as the coefficient of variation, and to estimate the effect of different laboratories. The analytic variation of Hb(mass) was 2.4% when tests were conducted in different laboratories, which reduced to 1.6% when the model accounted for between-laboratory differences. Adjustment of Hb(mass) values using quality controls achieved a comparable analytic variation of 1.7%. The majority of between-laboratory variation in Hb(mass) originated from the difference between hemoximeters, which could be eliminated using appropriate quality controls.
Related Concept Videos
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Uncertainty in Measurement: Accuracy and Precision
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Data Validation
Key parameters for method validation include:
Errors occurring during blood pressure monitoring
Several factors...