Related Experiment Video
Updated: Jun 2, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Surgical infection prophylaxis for left ventricular assist device implantation
Paul C Walker1, Daryl D DePestel, Nicholas A Miles
1Department of Pharmacy Services, University of Michigan Health System and College of Pharmacy, Ann Arbor, Michigan 48109–0008, USA. pcwalker@umich.edu
Background:
Antimicrobial prophylaxis is commonly administered to patients undergoing left ventricular assist device (LVAD) surgeries to prevent infectious complications. However, optimal surgical infection prophylaxis (SIP) for LVAD surgeries is not well defined.
Methods:
We conducted an electronic survey to characterize LVAD SIP used at different centers performing LVAD implantation.
Results:
Responses were received from 23 of 85 centers (27%). Of 21 centers that provided usable data about their LVAD SIP regimens for nonpenicillin allergic patients, 42.9% reported using a four-drug regimen (three antibiotics plus fluconazole), 23.8% reported using a three-drug regimen (three antibiotics or two antibiotics plus fluconazole), 23.8% reported using a regimen of two antibiotics, and 9.5% reported using vancomycin alone. A similar pattern was observed among SIP regimens for penicillin-allergic patients. Criteria for discontinuation of SIP and use of decolonization strategies also varied widely across centers.
Conclusions:
Our results demonstrate wide variability in LVAD SIP regimens and underscore the lack of consensus regarding best practice.
Related Concept Videos
Endocarditis III: Medical Management
Cardiomyopathy V: Interprofessional Care
Endocarditis IV: Nursing Management
Cardiac Catheterization III: Left Heart Catheterization
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Cardiac Catheterization IV: Nursing Management