Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Finite element analysis of the coupling between ossicular chain and mass loading for evaluation of implantable
Xuelin Wang1, Yujin Hu, Zhenlong Wang
1School of Mechanical Science and Engineering, Huazhong University of Science and Technology, No. 1037, Luoyu Road, Wuhan, Hubei 430074, China. wangxl@mail.hust.edu.cn
Abstract:
Finite element (FE) model is used to analyze the coupling effects between ossicular chain and transducer of implantable middle-ear hearing devices. The mass loading of the transducer is attached to the long process of the incus in the form of floating mass transducer (FMT) or applied near the incus-stapes joint by a magnet of contactless electromagnetic transducer (CLT). By changing placement of the transducer, crimping connection and damping parameter of the crimping mechanism, theoretical performances of the transducers were investigated on mechanical characteristics in two aspects: (1) displacement change at the stapes footplate, which describes the change in hearing due to placement of the transducer; (2) the equivalent pressure output of the transducer, which relates the footplate displacement driven by transducer to the sound pressure applied to a normal ear to produce that displacement. For the FMT with a less tight crimping connection or low supporting rigidity, a large drop of the sound-induced stapes displacement occurs at a specific frequency, with a peak reduction about 25.8 dB. A tight connection or high supporting rigidity shifts the drop of the stapes displacement to higher frequency. For the CLT, an electromagnetic transducer of 25 mg placed near the incus-stapes joint produces a maximum decrease of the stapes displacement around 16.5 dB. The equivalent sound pressure output and electromagnetic force requirement are proposed to produce the stapes displacement equivalent to that ear canal sound stimulus. The drop of the footplate displacement caused by mass loading effect can be recovered by the transducer stimulation over frequency range from 1500 Hz to 4000 Hz. The FE analysis reveals that enhancing the coupling stiffness between the clip and the ossicular chain is much helpful for maximizing the efficiency of the transducer stimulation.
Related Concept Videos
The Auditory Ossicles
The aptly named stapes look very much like a stirrup. The three ossicles are unique to mammals, and each plays a role in...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Impact Loading
In cases of elastic deformation,...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...