Related Experiment Video
Updated: Jun 2, 2026

Chemical Analysis of Water-accommodated Fractions of Crude Oil Spills Using TIMS-FT-ICR MS
Published on: March 3, 2017
A new direct Fourier transform infrared analysis of free fatty acids in edible oils using spectral reconstitution
Xiuzhu Yu1, F R van de Voort, Jacqueline Sedman
1College of Food Science and Engineering, Northwest A&F University, Shaanxi, China. xiuzhuyu1004@hotmail.com
Abstract:
A new transmission-based Fourier transform infrared (FTIR) spectroscopic method for the direct determination of free fatty acids (FFA) in edible oils has been developed using the developed spectral reconstitution (SR) technique. Conventional neat-oil and SR calibrations were devised by spiking hexanoic acid into FFA-free canola oil and measuring the response to added FFA at 1,712 cm(-1) referenced to a baseline at 1,600 cm(-1)(1,712 cm(-1)/1,600 cm(-1)). To compensate for the known oil dependency of such calibration equations resulting from variation of the triacylglycerol ester (C═O) absorption with differences in oil saponification number (SN), a correction equation was devised by recording the spectra of blends of two FFA-free oils (canola and coconut) differing substantially in SN and correlating the intensity of the ester (C═O) absorption at the FFA measurement location with the intensity of the first overtone of this vibration, measured at 3,471 cm(-1)/3,427 cm(-1). Further examination of the spectra of the oil blends by generalized 2D correlation spectroscopy revealed an additional strong correlation with an absorption in the near-infrared (NIR) combination band region, which led to the development of a second correction equation based on the absorbance at 4,258 cm(-1)/4,235 cm(-1). The NIR-based correction equation yielded superior results and was shown to completely eliminate biases due to variations in oil SN, thereby making a single FFA calibration generally applicable to oils, regardless of SN. FTIR methodology incorporating this correction equation and employing the SR technique has been automated.
Related Concept Videos
IR Frequency Region: Fingerprint Region
The...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
IR Spectrometers
Spectroscopy of Carboxylic Acid Derivatives
In the...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...