Related Experiment Video
Updated: Jun 2, 2026

In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
A formal comparison of different methods for establishing cut points to distinguish positive and negative samples in
Thomas Jaki1, John-Philip Lawo, Martin J Wolfsegger
1Medical and Pharmaceutical Research Unit, Deparment of Mathematics and Statistics, Lancaster University, Lancaster LA14YF, United Kingdom. jaki.thomas@gmail.com
Biotechnology derived therapeutics may induce an unwanted immune response leading to the formation of anti-drug antibodies (ADA). As a result the efficacy and safety of the therapeutic protein could be impaired. Neutralizing antibodies may, for example, affect pharmacokinetics of the therapeutic protein or induce autoimmunity. Therefore a drug induced immune response is a major concern and needs to be assessed during drug development. It is therefore crucial to have assays available for the detection and characterization of ADAs. These assays are used to classify samples in positive and negative samples based on a cut point. In this manuscript we investigate the performance of established and newly developed methods to determine a cut point in immunoassays such as ELISA through simulation and analysis of real data. The different methods are found to have different advantages and disadvantages. A robust parametric approach generally resulted in very good results and can be recommended for many situations. The newly introduced method based on mixture models yields similar results to the robust parametric approach but offers some additional flexibility at the expense of higher complexity.
Biotechnology derived therapeutics may induce an unwanted immune response leading to the formation of anti-drug antibodies (ADA). As a result the efficacy and safety of the therapeutic protein could be impaired. Neutralizing antibodies may, for example, affect pharmacokinetics of the therapeutic protein or induce autoimmunity. Therefore a drug induced immune response is a major concern and needs to be assessed during drug development. It is therefore crucial to have assays available for the detection and characterization of ADAs. These assays are used to classify samples in positive and negative samples based on a cut point. In this manuscript we investigate the performance of established and newly developed methods to determine a cut point in immunoassays such as ELISA through simulation and analysis of real data. The different methods are found to have different advantages and disadvantages. A robust parametric approach generally resulted in very good results and can be recommended for many situations. The newly introduced method based on mixture models yields similar results to the robust parametric approach but offers some additional flexibility at the expense of higher complexity.
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

