Related Experiment Video
Updated: Jun 2, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Substitute technology for reference substances in the analysis of impurities in cefonicid for injection with HPLC
1Anhui Institute for Food and Drug Control, Department of Antibiotics, Hefei, Anhui 230051, People's Republic of China. liwow@126.com
Abstract:
With HPLC using a diode array detector (DAD), a method of substitution for reference substances in impurity profiling control was developed that combined peak tracking by the correlation of spectra with application of correction factors for determination of each impurity. For qualitative analysis, two-dimensional (2D) standard spectrochromatographic data produced by HPLC-DAD were compared with sample data to develop 2D chromatographic spectral correlative maps so that the three target impurities were recognized without preparation and injection of reference solutions. For quantitative analysis, correction factors among cefonicid and the three impurities were established. The correction factors were 1.06 for 5-mercapto-1,2,3,4-tetrazole 1-methyl sulfonic acid detected at 255 nm, 0.77 for 7-aminocephalosporanic acid detected at 265 nm, and 0.97 for methoxycefonicid detected at 268 nm. The method could be used in analysis of related substances in cefonicid for injection without recourse to chemical reference standards of the three impurities.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Instrumentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...