Fusion of dynamic contrast-enhanced magnetic resonance mammography at 3.0T with X-ray mammograms: pilot study
Matthias Dietzel1, Torsten Hopp, Nicole Ruiter
1Institute of Diagnostic and Interventional Radiology, Friedrich-Schiller-University Jena, Erlanger Allee 101, D-07740 Jena, Germany. dietzelmatthias2@hotmail.com
Rationale And Objectives:
To evaluate the semi-automatic image registration accuracy of X-ray-mammography (XR-M) with high-resolution high-field (3.0T) MR-mammography (MR-M) in an initial pilot study.
Material And Methods:
MR-M was acquired on a high-field clinical scanner at 3.0T (T1-weighted 3D VIBE ± Gd). XR-M was obtained with state-of-the-art full-field digital systems. Seven patients with clearly delineable mass lesions >10mm both in XR-M and MR-M were enrolled (exclusion criteria: previous breast surgery; surgical intervention between XR-M and MR-M). XR-M and MR-M were matched using a dedicated image-registration algorithm allowing semi-automatic non-linear deformation of MR-M based on finite-element modeling. To identify registration errors (RE) a virtual craniocaudal 2D mammogram was calculated by the software from MR-M (with and w/o Gadodiamide/Gd) and matched with corresponding XR-M. To quantify REs the geometric center of the lesions in the virtual vs. conventional mammogram were subtracted. The robustness of registration was quantified by registration of X-MRs to both MR-Ms with and w/o Gadodiamide.
Results:
Image registration was performed successfully for all patients. Overall RE was 8.2mm (1 min after Gd; confidence interval/CI: 2.0-14.4mm, standard deviation/SD: 6.7 mm) vs. 8.9 mm (no Gd; CI: 4.0-13.9 mm, SD: 5.4mm). The mean difference between pre- vs. post-contrast was 0.7 mm (SD: 1.9 mm).
Conclusion:
Image registration of high-field 3.0T MR-mammography with X-ray-mammography is feasible. For this study applying a high-resolution protocol at 3.0T, the registration was robust and the overall registration error was sufficient for clinical application.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...