Reliability of semiautomatic centerline analysis versus manual aortic measurement techniques for TEVAR among
Objectives:
The study aimed to test whether reliability and inter-observer variability of preoperative measurements for thoracic endovascular aortic repair (TEVAR) among non-experts are improved by semiautomatic centerline analysis compared with manual assessment.
Methods:
Preoperative computed tomography (CT) angiographies of 30 patients with thoracic aortic disease (mean age 66.8 ± 11.6 years, 23 men) were retrospectively analysed in randomised order by one blinded vascular expert (reference standard) and three blinded non-expert readers. Aortic diameters were measured at four positions relevant to TEVAR using three measurement techniques (manual axial slices, manual multiplanar reformations (MPRs) and semiautomatic centerline analysis). Length measurements were performed using centerline analysis. Reliability was calculated as absolute measurement deviation (AMD) from reference standard and inter-observer variability as coefficient of variance (CV) among non-expert readers.
Results:
For axial, MPR and centerline techniques, mean AMD was 7.3 ± 7.7%, 6.7 ± 4.5% and 4.7 ± 4.8% and mean CV was 5.2 ± 4.2%, 5.8 ± 4.8% and 3.9 ± 5.4%. Both AMD and CV were significantly lower for centerline analysis compared with axial technique (p = 0.001/0.042) and MPR (p = 0.009/0.003). AMD and CV for length measurements by centerline analysis were 3.2 ± 2.8% and 2.6 ± 2.4%, respectively. Centerline analysis was significantly faster than MPR (p < 0.001).
Conclusions:
Semiautomatic centerline analysis provides the most reliable and least variable diameter and length measurements among non-experts in candidates for TEVAR.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.