Summary

Single crystals of europium scandate (EuScO3) were grown and analyzed. The study revealed a defect-type structure with europium deficiency and oxygen vacancies, refining previous findings.

Related Concept Videos

Methods of Documentation V: CBE01:23

Methods of Documentation V: CBE

Charting by Exception, or CBE, is a method of documentation used in healthcare, particularly in nursing, that focuses on documenting only significant or abnormal findings rather than recording every detail. This approach aims to streamline the documentation process, improve efficiency, and ensure that healthcare providers can quickly identify deviations from normalcy in patient assessments.
In CBE, healthcare professionals establish predefined standards of practice that define what constitutes...
Econometric Views (EViews)01:29

Econometric Views (EViews)

Econometric Views, often stylized as EViews, is a package that merges statistical analysis with econometric studies. It is designed to provide tools for time series analysis, forecasting, and econometric model simulation. The software originated from MicroTSP software and has evolved significantly since its inception in 1981. The history of EViews is marked by a continuous effort to enhance its computational speed and user interface. It was initially developed for large computing systems but...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Margin of Error01:27

Margin of Error

The margin of error is also called the maximum error of an estimate. The margin of error is the maximum possible or expected difference between the observed sample parameter value and the actual population parameter value. For proportion, it is the maximum difference between the value of sample proportion obtained from the data and the true value of population proportion. As the true value of the population parameter is not known, the margin of error is calculated using the sample statistic.
Enzyme-Linked Immunosorbent Assay01:33

Enzyme-Linked Immunosorbent Assay

In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen.  Enzyme-substrate reaction allows the antigen to be visualized or quantified.
EDTA: Conditional Formation Constant01:09

EDTA: Conditional Formation Constant

Each EDTA molecule has six binding sites: four carboxyl groups and two amino groups. The fully protonated form of EDTA is represented as H6Y2+. However, it can exist in different forms, H5Y+, H4Y, H3Y−, H2Y2−, and HY3−, depending on the pH of the solution. In very basic solutions with pH > 10.17, the fully deprotonated form, Y4−, is the predominant species that readily complexes with metal ions in a 1:1 ratio.
For the equilibrium reaction of the metal with the Y4− form of EDTA, the formation...