Background:
Transradial percutaneous coronary procedures may be effectively performed through the right radial approach (RRA) or the left radial approach (LRA), but data on radiation dose absorbed by operators comparing the two approaches are lacking. The aim of the present study was to evaluate radiation dose absorbed by operators during coronary procedures through the RRA and LRA.
Methods And Results:
Three operators were equipped with 5 different dosimeters (left wrist, shoulder, thorax outside the lead apron, thorax under the lead apron, and thyroid) during RRA or LRA for coronary procedures. Each month, the dosimeters were analyzed to determine the radiation dose absorbed. From February to December 2009, 390 patients were randomly assigned to the RRA (185 patients; age, 66±11 years) or the LRA (185 patients; age, 66±11 years). There were no significant differences in fluoroscopy time (for RRA, 369 seconds; interquartile range, 134 to 857 seconds; for LRA, 362 seconds; interquartile range, 142 to 885 seconds; P=0.58) between the 2 groups. There were no significant differences in monthly radiation dose at the thorax (0.85±0.46 mSv for RRA and 1.12±0.78 mSv for LRA, P=0.33), at the thyroid (0.36±0.2 mSv for RRA and 0.34±0.3 mSv for LRA, P=0.87), and at the shoulder (0.73±0.44 mSv for RRA and 0.94±0.42 mSv for LRA, P=0.27). The dose at the wrist was significantly higher for the RRA (2.44±1.12 mSv) compared with the LRA (1±0.8 mSv, P=0.002). In both radial approaches, the thoracic radiation dose under the lead apron was undetectable.
Conclusions:
Compared with RRA, LRA for coronary procedures is associated with similar radiation dose for operators at the body, shoulder, or thyroid level, with a possible significant advantage at the wrist. The cumulative radiation dose for both approaches is well under to the annual dose-equivalent limit.
Clinical Trial Registration:
URL: http://www.clinicaltrials.gov. Unique identifier: NCT00282646.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization II: Right Heart Catheterization
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization III: Left Heart Catheterization