Related Experiment Video
Updated: Jun 1, 2026

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
3D-high resolution manometry of the esophagogastric junction
M A Kwiatek1, J E Pandolfino, P J Kahrilas
1Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611-2951, USA. monika.kwiatek@gmail.com
Background:
The esophagogastric junction (EGJ) is a complex structure that challenges accurate manometric recording. This study aimed to define EGJ pressure morphology relative to the squamocolumnar junction (SCJ) during respiration with 3D-high resolution manometry (3D-HRM).
Methods:
A 7.5-cm long 3D-HRM array with 96 independent solid-state pressure sensors (axial spacing 0.75 cm, radial spacing 45°) was used to record EGJ pressure in 15 normal subjects. Concurrent videofluoroscopy was used to localize the SCJ marked with an endoclip. Ex vivo experiments were done on the effect of bending the probe to match that seen fluoroscopically.
Key Results:
3D-high resolution manometry EGJ pressure recordings were dominated by an asymmetric pressure peak superimposed on the lower esophageal sphincter (LES) attributable to the crural diaphragm (CD). Median peak CD pressure at expiration and inspiration (51 and 119 mmHg, respectively) was much greater in 3D-HRM than evident in HRM with circumferential pressure averaging. Esophagogastric junction length, defined as the zone of circumferential pressure exceeding that of adjacent esophagus or stomach was also substantially shorter (2.4 cm) than evident in conventional HRM. No consistent circumferential EGJ pressure was evident distal to the SCJ in 3D-HRM recordings and ex vivo experiments suggested that the intra-gastric pressure peak seen contralateral to the CD related to bending the assembly rather than the sphincter per se.
Conclusions & Inferences:
3D-high resolution manometry demonstrated a profoundly asymmetric and vigorous CD component to EGJ pressure superimposed on the LES. Esophagogastric junction length was shorter than evident with conventional HRM and the distal margin of the EGJ sphincteric zone closely correlated with the SCJ.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Esophageal Achalasia
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Gastric Emptying