Related Experiment Video
Updated: Jun 1, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Dielectric barrier discharge molecular emission spectrometer as multichannel GC detector for halohydrocarbons
Abstract:
A novel microplasma molecular emission spectrometer based on an atmospheric pressure dielectric barrier discharge (DBD) is described and further used as a promising multichannel GC detector for halohydrocarbons. The plasma is generated in a DBD device consisting of an outer electrode (1.2 mm in diameter) and an inner electrode (1.7 mm in diameter) within a small quartz tube (3.0 mm i.d. × 5.0 mm o.d. × 50 mm), wherein analyte molecules are excited by the microplasma to generate molecular emission. Therefore, the analytes are selectively and simultaneously detected with a portable charge-coupled device (CCD) via multichannel detection of their specific emission lines. The performance of this method was evaluated by separation and detection of a model mixture of chlorinated hydrocarbons (CHCl(3) and CCl(4)), brominated hydrocarbons (CH(2)Br(2) and CH(2)BrCH(2)Br), and iodinated hydrocarbons (CH(3)I and (CH(3))(2)CHI) undergoing GC with the new detector. The completely resolved identification of the tested compounds was achieved by taking advantages of both chromatographic and spectral resolution. Under the optimized conditions with the CCD spectrometer set at 258, 292, and 342 nm channels for determination of chlorinated hydrocarbons, brominated hydrocarbons, and iodinated hydrocarbons, respectively, this detector with direct injection provided detection limits of 0.07, 0.06, 0.3, 0.04, 0.05, and 0.02 μg mL(-1) for CCl(4), CHCl(3), CH(2)Cl(2), CH(3)I, CH(3)CH(2)I, and (CH(3))(2)CHI, respectively.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.

