Double balloon enteroscopy to retrieve an accidentally swallowed dental reamer deep in the jejunum
Shingo Kato1, Kazuhito Kani, Hidehiko Takabayashi
1Shingo Kato, Kazuhito Kani, Hidehiko Takabayashi, Ryuichi Yamamoto, Koji Yakabi, Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Saitama 350-8550, Japan.
Abstract:
Accidentally swallowed foreign objects are not uncommon but difficult to manage without complications. We describe the case of a 68 year old man who accidentally a swallowed sharp-pointed dental reamer that had reached deep in his jejunum. Double balloon enteroscopic retrieval was performed with polypectomy snare but the reamer was entangled in the wire loop of the snare and penetrated the jejunal wall. After releasing the reamer by pushing and pulling the snare for approximately 30 min, the reamer was retrieved with biopsy forceps. This is the first report of double balloon enteroscopic removal of a dental reamer. Furthermore, this is a novel case with regard to decision making in situations when sharp objects are swallowed.
Related Concept Videos
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Endoscopic Procedures II: Colonoscopy