Six sigma: process of understanding the control and capability of ranitidine hydrochloride tablet

Ar Chabukswar1, Sc Jagdale, Bs Kuchekar

  • 1MAEER's Maharashtra Institute of Pharmacy, MIT Campus, Paud Road, Kothrud, Pune - 411 038, India.

Related Concept Videos

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules01:18

Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules

Bioequivalence in generic drugs, such as tablets and capsules, refers to their pharmaceutical equivalence to the brand-name counterparts. However, for therapeutic equivalence, manufacturers must also consider physical attributes like size, shape, and weight (FDA Guidance for Industry, December 2003). Discrepancies in these aspects could impact patient compliance and cause medication errors. For instance, swallowing difficulties, often experienced with larger tablets or capsules, can lead to...
Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
Interpreting R Charts01:22

Interpreting R Charts

R chart, or range chart, is a fundamental tool in statistical process control used to monitor the variability within a process. It complements the X-bar (x̄) chart by focusing on the range of the data, rather than individual values, providing a clear picture of the process dispersion over time.
An R chart plots the range of subsets of measurements collected from a process. Each point on the chart represents the range—defined as the difference between the maximum and minimum values—of a sample...
Dosage Regimen: Individualization01:24

Dosage Regimen: Individualization

Individualization in dosing regimens is the customization of medication doses for individual patients. Its necessity arises from the goal of maximizing therapeutic benefits while minimizing risks. This approach is pivotal because human responses to drugs can vary widely; what is effective for one person may be inadequate or excessive for another. Interpatient (intersubject) variability refers to differences in drug responses between individuals, while intrapatient (intrasubject) variability...
Modified-Release Drug Delivery Systems: Rate-Programmed I01:22

Modified-Release Drug Delivery Systems: Rate-Programmed I

Rate-programmed drug delivery systems (DDS) are designed to release drugs at specific, controlled rates to maintain consistent therapeutic levels. These systems are categorized based on their release mechanisms, including dissolution-controlled DDS, diffusion-controlled DDS, and combined dissolution-diffusion-controlled DDS.In dissolution-controlled DDS, the release rate depends on the slow dissolution of the drug itself or the surrounding matrix. Drugs with inherently slow dissolution rates,...