Related Experiment Video
Updated: Jun 1, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
[Dynamics of oxygen uptake during a 100 m front crawl event, performed during competition ]
Chadi Jalab1, Carina Enea, Nathalie Delpech
1Université de Poitiers, Laboratoire des adaptations physiologiques aux activités physiques (LAPHAP, EA 3813), F-86000 Poitiers, France.
Abstract:
The main purpose of this study is to estimate the dynamics of oxygen uptake (VO2) during a 100 m front crawl event, performed in competition conditions. Eleven trained swimmers participated in 2 separate sessions, in a 25 m swimming pool. Maximal oxygen uptake (VO2max) was determined during a 400 m maximal event. Swimmers also performed a 100 m front crawl in competition conditions, and then, 3 tests (25, 50, and 75 m) following the pacing strategy of the 100 m event. To be free of technical constraints, VO2 was not measured during the tests, but before and just at the end of each test with a 1 min breath-by-breath method. Each post-test VO2 measurement (after 25, 50, 75, and 100 m) allows us to reconstruct the VO2 kinetics of the 100 m performance. Our results differ from previous studies in that VO2 increases faster in the first half of the race (at 50 m, VO2 ≈ 94% VO2max), reaches VO2max at the 75 m mark; then a decrease in VO2 corresponding to 7% of VO2max appears during the last 25 m. These differences are supposed to be mainly the consequences of the adoption of technical elements and a pacing strategy similar to competition conditions. In the future, these observations may lead to different considerations of the bioenergetic contributions.
Related Concept Videos
Oxygen Transport in the Blood
Oxygen Requirements and Growth Patterns
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...