Related Experiment Video
Updated: Jun 1, 2026

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Chlorine isotope analysis of organic contaminants using GC-qMS: method optimization and comparison of different
Biao Jin1, Christine Laskov, Massimo Rolle
1Center for Applied Geosciences, University of Tübingen, Tübingen, Germany.
Abstract:
Compound-specific online chlorine isotope analysis of chlorinated hydrocarbons was evaluated and validated using gas chromatography coupled to a regular quadrupole mass spectrometer (GC-qMS). This technique avoids tedious off-line sample pretreatments, but requires mathematical data analysis to derive chlorine isotope ratios from mass spectra. We compared existing evaluation schemes to calculate chlorine isotope ratios with those that we modified or newly proposed. We also tested systematically important experimental procedures such as external vs. internal referencing schemes, and instrumental settings including split ratio, ionization energy, and dwell times. To this end, headspace samples of tetrachloroethene (PCE), trichloroethene (TCE), and cis-dichloroethene (cDCE) at aqueous concentrations in the range of 20-500 μg/L (amount on-column range: 3.2-115 pmol) were analyzed using GC-qMS. The results (³⁷Cl/³⁵Cl ratios) showed satisfying to good precisions with relative standard deviations (n = 5) between 0.4‰ and 2.1‰. However, we found that the achievable precision considerably varies depending on the applied data evaluation scheme, the instrumental settings, and the analyte. A systematic evaluation of these factors allowed us to optimize the GC-qMS technique to determine chlorine isotope ratios of chlorinated organic contaminants.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Isotope Effect
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...

