Related Experiment Video
Updated: Jun 1, 2026

All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
Published on: January 19, 2018
Electronic spectroscopy of molecules in superfluid helium nanodroplets: an excellent sensor for intramolecular charge
D Pentlehner1, R Riechers, A Vdovin
1Institut für Physikalische und Theoretische Chemie Universität Regensburg, 93040 Regensburg, Germany.
Abstract:
Electronic spectra of molecules doped into superfluid (4)He nanodroplets reveal important details of the microsolvation in superfluid helium. The vibrational fine structure in the electronic spectra of phthalocyanine derivatives and pyrromethene dye molecules doped into superfluid helium droplets have been investigated. Together with previous studies on anthracene derivatives [J. Chem. Phys.2010, 133, 114505] and 3-hydroxyflavone [J. Chem. Phys.2009, 131, 194307], the line shapes vary between two limiting cases, namely, sharp Lorentzians and nonresolved vibrational fine structure. All different spectral signatures are initiated by the same effect, namely, the change of the electron density distribution initiated by the electronic excitation. This change can be quantified by the difference of the electrostatic moments of the molecule in the electronic ground state and the corresponding Franck-Condon point in the excited state. According to the experimental data, electronic spectroscopy suffers from drastic line broadening when accompanied by significant changes of the charge distribution, in particular, changes of the dipole moment. Vice versa, the vibrational fine structure in electronic spectra of molecules doped into helium droplets is highly sensitive to changes of the electron density distribution.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
08:51Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
Published on: August 18, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
UV–Vis Spectroscopy: Molecular Electronic Transitions