Dynamics and performance of fast linear scan anodic stripping voltammetry of cd, pb, and cu using in situ-generated ultrathin mercury films
Related Experiment Video
Updated: Jun 1, 2026

Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes
Published on: June 30, 2019
1Research Center, YSI, Inc., P.O. Box 279, Yellow Springs, Ohio 45387.
Abstract:
The dynamics of fast linear scan (LS) ASV for the simultaneous detection of Cd, Pb, and Cu was investigated at various scan rates (0.5-10 V/s) and at different metal ion concentrations (50-800 nM) utilizing ultrathin mercury films (9 nm) at a conventional size (d(0) = 1 mm) electrode. Results of the investigation show that when the thin films were utilized, diffusion of metals through the mercury film was not the rate-limiting step of the stripping process at moderate to fast scan rates (0.5-10 V/s). A fairly linear relationship between the peak height and scan rate was observed at scan rates (0.5-10 V/s) beyond the upper limit of the theoretical model for the behavior of LS-ASV. In addition, peak width at half-height (b(1/2)) as low as 33 mV was achieved at 0.5 V/s. The behavior of LS-ASV in terms of peak width at these scan rates is thus different from what the theoretical model of LS-ASV would have predicted. For the ultrathin mercury films, at least two additional factors, kinetics and concentration, have significant effects on practical LS-ASV. Experimental results show that the stripping process of Cu was primarily kinetic-controlled for fast scans, while those for Cd and Pb were dependent on both scan rates and concentrations. The ultrathin mercury film resulted in a significant enhancement of the ratio of signal-to-baseline slope (i(p)/Δi(b), a ratio used to measure the effectiveness of discrimination of the peak signal against the steep sloping baseline in LS-ASV) for Cd and Pb stripping peaks, but only a slight enhancement for Cu stripping peaks. The optimal performance of LS-ASV in terms of sensitivity, peak width, and enhancement of the i(p)/Δi(b) ratio for the three metals was achieved at 2 V/s. Because of the high reproducibility of the background currents of the stable in situ MTFs, background subtraction was carried out at 2 V/s with little hysteresis. This feature, combined with the enhancement of the i(p)/Δi(b) ratio at the fast scan rate of 2 V/s, allowed for the detection of sub-ppb levels of Cd, Pb, and Cu at a deposition time of 2 min.
More Related Videos
08:31Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope (AFM-SECM)
Published on: February 10, 2021
10:59Tracking Electrochemistry on Single Nanoparticles with Surface-Enhanced Raman Scattering Spectroscopy and Microscopy
Published on: May 12, 2023
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Pulse Voltammetry
Electrodeposition
Electrodeposition can...