Identification of chemical interferences in aldehyde and ketone determination using dual-wavelength detection

W Pötter1, U Karst

  • 1Lehrstuhl für Analytische Chemie, Anorganisch-Chemisches Institut, Westfälische Wilhelms-Universität Münster, Wilhelm-Klemm-Strasse 8, 48149 Münster, Germany.

Related Concept Videos

IR and UV–Vis Spectroscopy of Aldehydes and Ketones01:29

IR and UV–Vis Spectroscopy of Aldehydes and Ketones

Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the C=O stretching, is...
NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones01:15

NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones

In aldehydes, the hydrogen atom connected to the carbonyl carbon helps distinguish aldehydes from other carbonyl compounds using ¹H NMR spectroscopy. The closeness of aldehydic hydrogen to the electrophilic carbonyl carbon highly deshields the hydrogen atom causing its signal to appear around 10 ppm in the ¹H NMR spectra. α hydrogens split the aldehydic proton signal, which helps identify the number of α hydrogens in the molecule. For instance, one α hydrogen creates a doublet for an aldehydic...
Mass Spectrometry: Aldehyde and Ketone Fragmentation01:09

Mass Spectrometry: Aldehyde and Ketone Fragmentation

In mass spectrometry, the fragmentation of aliphatic aldehydes and ketones generally occurs through three key mechanisms: α-cleavage, inductive cleavage, and the McLafferty rearrangement.
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Crossed Aldol Reaction Using Strong Bases: Directed Aldol Reaction00:56

Crossed Aldol Reaction Using Strong Bases: Directed Aldol Reaction

The reaction between two different carbonyl compounds comprising α hydrogen in the presence of a strong base like lithium diisopropylamide (LDA) to form a crossed aldol product is known as a directed aldol reaction. The directed aldol reaction is depicted in Figure 1.