Fritless packed columns for capillary electrochromatography: separation of uncharged compounds on hydrophobic
C Fujimoto1, Y Fujise, E Matsuzawa
1Department of Chemistry, Hamamatsu University School of Medicine, Hamamatsu 431-31, Japan.
Abstract:
A novel column is described that does not require frits to keep packing material within a capillary. A continuous bed is prepared in situ in aqueous solution by radical copolymerization of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid (the resultant gel is denoted poly(AMPS-co-IPAAm). N,N'-Methylenebisacrylamide is used for cross-linking. On the application of an electrical field, electroosmotic flow (EOF) is developed in the bed along the capillary, where fluid propulsion would be otherwise difficult to achieve. The resultant EOF transports neutral compounds through the column without forcing the gel out of the capillary. Examination of the fluid motion in the continuous bed using a video microscope system and an image processor shows a relatively flat flow profile of EOF. The bed functions as the stationary phase for reversed-phase capillary electrochromatography (CEC). This new approach is an alternative to packed capillary columns which have been used previously in CEC. A high efficiency is obtained for a steroid which is separated on a 4.0% total monomer concentration (T), 10.0% degree of cross-linking (C), and 10.0% mole fraction of AMPS in the total monomer (S), poly(AMPS-co-IPAAm) column. A mixture of polyaromatic hydrocarbons is separated on a 6.9% T, 5.8% C, and 5.5% S poly(AMPS-co-IPAAm) column. The capacity factor of benzo[a]pyrene increases from 0.63 to 1.91 as the acetonitrile content in a Tris-boric acid buffer is decreased from 45 to 30% (v/v). The run-to-run RSD of analyte migration time is less than 0.73%, and the day-to-day RSD is acceptable. Potential benefits of this approach are also mentioned.
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...