Related Experiment Video
Updated: Feb 11, 2026

Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Valve replacement for severe aortic stenosis with low transvalvular gradient and left ventricular ejection fraction
Giuseppe Tarantini1, Elisa Covolo, Renato Razzolini
1Section of Cardiology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padua, University Hospital, Pauda, Italy. giuseppe.tarantini.1@unipd.it
Background:
Severe aortic stenosis with a low transvalvular gradient and preserved left ventricular ejection fraction (LVEF) is often misdiagnosed, leading to undertreatment of such patients with no clear indication for surgical intervention. This study investigated the outcome of aortic valve replacement (AVR) in patients with severe aortic stenosis and a low transvalvular gradient despite normal LVEF.
Methods:
Between 1985 and 2008, we evaluated 73 patients who underwent AVR compared with 29 patients who did not. Overall, aortic valve area was 1.0 cm2 or smaller, LVEF was 0.50 or higher, and transvalvular gradient was 30 mm Hg or less. Multivariate and Cox analyses were used to compare these two groups according to AVR.
Results:
Compared with controls, AVR patients were younger and with higher body mass index. Coronary artery bypass grafting was performed simultaneously in 38 AVR patients (52%). At follow-up (median, 42 months; interquartile range, 23 to 75 months), survival was longer in AVR patients. By Cox analysis, AVR remained a major predictor of lower mortality (hazard ratio, 0.237; 95% confidence interval, 0.119 to 0.470; p<0.0001).
Conclusions:
In patients with severe aortic stenosis and low transvalvular gradient despite a normal LVEF, AVR was associated with significant improvement in long-term survival and functional status and with a low operative mortality.
Related Concept Videos
Partial Fractions
Continuous Renal Replacement Therapy
Mitral Stenosis I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Subcellular Fractionation
Differential Centrifugation
Differential centrifugation is...