Related Experiment Video
Updated: Jun 1, 2026

Non-invasive Imaging of Acute Allograft Rejection after Rat Renal Transplantation Using 18F-FDG PET
Published on: April 28, 2013
Magnetic resonance with diffusion-weighted imaging in the evaluation of transplanted kidneys: preliminary findings
S Palmucci1, L A Mauro, P Veroux
1Section of Radiological Sciences, Maternal-Child and Radiological Sciences Department, University Hospital Policlinico-Vittorio Emanuele, Catania, Italy. spalmucci@sirm.org
Background:
The aim of this study was to compare values of apparent diffusion coefficient (ADC) and diffusion (D) with renal function indexes, in a population of kidney transplant recipients who underwent magnetic resonance with diffusion-weighted imaging (DWI) of the transplanted graft.
Materials And Methods:
We studied 21 patients using a 1.5-Tesla magnetic resonance; DWI sequences were acquired with several b-values. Patients were divided into 3 groups by their creatinine clearance values: group A, clearance >60 mL/min; group B, clearance >30 and ≤60 mL/min; and group C, clearance ≤30 mL/min. ADCs values between groups were compared using the Mann-Whitney U test. Receiver operating characteristic (ROC) curves were created for prediction of normal renal function (group A) and renal failure (group C).
Results:
Comparing mean values of ADC between groups A and C, we observed a difference (P=0.0012), with higher values in group A. Regarding mean values of D, we observed a difference between groups A and C (P=0.022). In the comparison between contiguous groups, we observed no difference for ADC and D values. In the prediction of normal clearance values (group A), ROC curve showed an area under curve (AUC) of 0.861, with a sensitivity of 88.89% and specificity of 75% using a threshold ADC value ≥2.1 × 10(-3) mm(2)/sec. For prediction of normal clearance values (group A), ROC curve showed an AUC of 0.787, with a sensitivity of 77.8% and specificity of 83.3% using a threshold D value ≥2.3 × 10(-3) mm(2)/sec.
Conclusion:
Although studies with a larger number of patients are needed, DWI represents a promising tool for noninvasive assessment of renal function. An ADC ≥ 2.1 × 10(-3) mm(2)/sec and a D ≥ 2.3 × 10(-3) mm(2)/sec may be used as a threshold for predicting normal clearance.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Kidney Transplant I: Introduction
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...

