Related Experiment Video
Updated: Jun 1, 2026

A Hydrogel Construct and Fibrin-based Glue Approach to Deliver Therapeutics in a Murine Myocardial Infarction Model.
Published on: June 14, 2015
Postexplant residual cavity hemostasis with a TachoSil patch
P De Rosa1, G Valeriani, G Barbato
1A.O.U. OO. RR. San Giovanni di Dio and Ruggi D'Aragona Hospital, Salerno-O.U. General Surgery and Renal Transplantation, Napoli, Italy. paride.derosa@sangiovannieruggi.it
Abstract:
Intracapsular nephrectomy as the standard explant technique for a unfunctional graft is associated with intra- and postoperative complications due mainly to hemorrhage, fluid collections, effusions from damaged tissues and the residual cavity. We have reported herein a positive experience with the use of a collagen medical sponge patch into the surgical site for hemostasis. Use of this device produced a reduction in postoperative bleeding and collections with shortened time of drainage, reduced infection risk, and earlier discharge.