Related Experiment Video
Updated: Jun 1, 2026

The Lower Body Positive Pressure Treadmill for Knee Osteoarthritis Rehabilitation
Published on: July 22, 2019
Physiological responses to body weight--supported treadmill exercise in healthy adults
Martin D Hoffman1, Haylee E Donaghe
1Department of Physical Medicine and Rehabilitation, Department of Veterans Affairs, Northern California Health Care System, and University of California Davis Medical Center, Sacramento, CA 95655-1200, USA. martin.hoffman@va.gov
Objective:
To determine whether the relationships of heart rate, rating of perceived exertion (RPE), and ground reaction forces (GRFs) with oxygen consumption rate (Vo(2)) during treadmill exercise are altered by partial body weight support (BWS) via lower-body positive pressure.
Design:
Repeated-measures design.
Setting:
Exercise physiology laboratory.
Participants:
Healthy, active adults (N=12); mean age ± SD, 45.1±12.6 years.
Interventions:
Not applicable.
Main Outcome Measures:
Vo(2), heart rate, RPE, and GRFs were measured during walking and running at 3 levels (0%, 25%, 50%) of BWS. Before exercise, standing heart rate and blood pressure were measured under each BWS condition.
Results:
Standing heart rates were 7 beats/min lower (P<.05) and systolic blood pressures were 10mmHg higher (P<.001) at 50% BWS compared with 0% BWS, but mean blood pressure while standing and the relationship of heart rate with Vo(2) during walking and running were not altered by BWS. While walking, the RPE at a Vo(2) of 10 mL · kg(-1) · min(-1) was statistically lower (P<.05) at 0% BWS compared with 25% and 50% BWS (mean values, 7 vs 8 points), but RPE was not different among conditions while running at a Vo(2) of 25 mL · kg(-1) · min(-1). Peak normal GRFs at specified Vo(2) levels and RPE values were reduced (P<.05) with increasing BWS for walking and running.
Conclusions:
Because partial BWS does not alter the relationship of heart rate with Vo(2) during exercise and has minimal effect on the relationship of RPE with Vo(2), training heart rate and RPE values do not appear to require adjustment with partial BWS. Reduced GRFs at specified Vo(2) levels from partial BWS suggest that there are important clinical applications of this technology.
More Related Videos
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...