Related Experiment Video
Updated: Jun 1, 2026

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Using multiple short-end injections to develop fast electrophoretic separations--applications in iodide analysis
Luciano Vitali1, Bethânia L Horst, Melina Heller
1Department of Chemistry, Federal University of Santa Catarina, Florianopolis, SC, Brazil.
Abstract:
The aim of this study was to develop a fast CE separation method by using multiple short-end injections in a capillary coated with quaternary ammonium chitosan (HACC), in order to determine the iodide content of pharmaceutical formulations. The BGE was composed of 20 mM tris(hydroxymethyl)aminomethane and 11 mM hydrochloric acid, at pH 8. The internal standard used was thiocyanate. Separations were performed in a fused silica capillary (32 cm total length, 8.5 cm effective length and 50 μm i.d.) coated with HACC and direct UV detection at 220 nm. EOF was modified by flushing the capillary with polymeric solution, resulting in a semi-permanent coating of controlled and stable EOF. The EOF was anodic at pH 8. Different strategies, using single and multiple injection short-end configurations, were studied to develop a CE method that resulted in a maximum number of iodide samples analyzed per hour: one plug and flush (Sflush) 35 samples/h, one plug without flush (SWflush) 76 samples/h, four plugs and flush (Mflush) 61 samples/h, and four plugs without flush (MWflush) 80 samples/h. Using the multiple injection configuration, it was possible to inject up to four plugs using spacer electrolytes with good separation efficiency and selectivity. The voltage application time needed to separate the eight peaks (iodide and thiocyanate) with MWflush was only 12s. The method was validated and samples were analyzed using MWflush. Good linearity (R(2)>0.999); a limit of detection 0.4 mg L(-1); intermediate precision better than 3.8% (peak area) and recovery in the range of 99-102% were obtained.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
High-Performance Liquid Chromatography: Elution Process