Air leak is associated with poor adherence to autoPAP therapy
Alexandra Valentin1, Shyam Subramanian, Stuart F Quan
1Southern Arizona Veterans Administration Healthcare System, Tucson, AZ, USA.
Study Objectives:
To our knowledge, a systematic study of the effect of air leak on adherence to auto-titrating positive airway pressure (autoPAP) therapy has not been reported. We hypothesized that in patients with obstructive sleep apnea (OSA), greater levels of air leak were associated with poor adherence to autoPAP therapy.
Design:
Retrospective cohort study
Setting:
Academic Center
Participants:
Ninety-six consecutive patients with high probability for OSA.
Interventions:
N/A.
Measurements:
Patients with OSA received 1 week of autoPAP therapy following which both adherence data and air leak information was downloaded from the device. Continuous positive airway pressure (CPAP) therapy was issued for a 5-week period with pressure determined by 90th percentile of that delivered during autoPAP therapy. Adequate adherence was defined as average usage > 4 h per night on all nights.
Results:
Forty-three patients were adherent to autoPAP therapy (350 ± 67[SD] min/day), whereas 53 patients were not (122 ± 65 min/day; P < 0.0001). Air leak that was adjusted for pressure delivered was greater in non-adherent patients (7.0 ± 3.5 L/min/cm H(2)O) than that in adherent patients (4.9 ± 1.7 L/min/cm H(2)O; P < 0.0001). Greater residual respiratory events (measured as autoPAP-derived hypopnea index) and proportion of time spent at large leak levels were associated with non-adherence. Patients who were adherent to autoPAP therapy received higher average therapeutic pressures from the autoPAP device than non-adherent patients. Multivariate logistic regression revealed that higher levels of air leak were associated with non-adherence to autoPAP therapy (odds ratio 1.43; 95% CI, 1.03, 1.98; P = 0.03). Moreover, adherence to autoPAP therapy was strongly correlated with subsequent adherence to CPAP therapy (R(2) = 0.74; P < 0.0001).
Conclusion:
Air leak was associated with poor adherence to autoPAP therapy. We speculate that air leak could be a potential target for future studies aimed at enhancing adherence to autoPAP therapy.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Atelectasis II: Pathophysiology
Acute Respiratory Failure-IV
Breathing