Updated: Jun 1, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
07:45

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report

Published on: August 4, 2022

Ilizarov hip reconstruction without external fixation: a new technique.

A H Krieg1, U Lenze, C C Hasler

  • 1Paediatric Orthopaedic Department, University Children's Hospital (UKBB), P. O. Box, Roemergasse 8, 4005 Basel, Switzerland.

Journal of Children'S Orthopaedics
|June 2, 2011
PubMed
Summary

This study introduces a novel Ilizarov hip reconstruction technique using only internal implants, offering a patient-friendly alternative to traditional external fixation methods for hip dislocation. The new approach resulted in successful leg equalization and improved gait without complications.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[15/f-Progressive knee pain in a patient with knock knees : Preparation for the Fellowship Examination: case 9].

Der Orthopade·2020
Same author

Quantitative signal intensity ratios to distinguish between subfascial lipoma and atypical lipomatous tumor/well-differentiated liposarcoma using short-tau inversion recovery (STIR) MRI.

Diagnostic and interventional imaging·2020
Same author

[Total endoprosthetic replacement of femur, humerus and tibia].

Der Orthopade·2019
Same author

[Slipped capital femoral epiphysis-etiology and pathogenesis].

Der Orthopade·2019
Same author

Treatment of early onset spinal deformities with magnetically controlled growing rods: a single centre experience of 30 cases.

Journal of children's orthopaedics·2019
Same author

A new technique for correction of leg length discrepancies in combination with complex axis deformities of the lower limb using a lengthening nail and a locking plate.

Journal of children's orthopaedics·2018

Area of Science:

  • Orthopedic surgery
  • Reconstructive surgery

Background:

  • The Ilizarov hip reconstruction is a recognized salvage procedure for chronically dislocated hips.
  • Traditional Ilizarov hip reconstruction relies on external fixation, which is associated with a high complication rate.
  • Fully implantable devices are advantageous but have not been used for Ilizarov hip reconstruction until now.

Purpose of the Study:

  • To present a novel technique for Ilizarov hip reconstruction utilizing exclusively internal implants.
  • To evaluate the feasibility and patient outcomes of this new internal fixation method.

Main Methods:

  • A 14-year-old patient with spina bifida and significant leg length discrepancy underwent Ilizarov hip reconstruction without external fixation.
  • A locking compression plate stabilized the proximal femoral osteotomy.
Keywords:
GaitHip dislocationIlizarov techniqueLimb lengtheningMethodsOsteotomySurgery

Related Experiment Videos

Last Updated: Jun 1, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
07:45

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report

Published on: August 4, 2022

  • A motorized intramedullary nail facilitated the distal osteotomy for lengthening and varization.
  • Main Results:

    • The procedure achieved a healing index of 33 days/cm.
    • Full weight-bearing was attained at 6 months post-surgery.
    • One-year follow-up demonstrated improved gait, leg length equalization, reduced pain, and high patient satisfaction with cosmetic outcomes.
    • No complications were reported.

    Conclusions:

    • Exclusive use of internal implants for Ilizarov hip reconstruction is a viable and patient-preferred alternative.
    • This technique offers a less complicated and more comfortable solution compared to external fixation.
    • Potential limitations may arise due to specific geometric patient conditions.