Development of an amperometric detector for packed capillary column supercritical fluid chromatography
S R Wallenborg1, K E Markides, L Nyholm
1Department of Analytical Chemistry, Uppsala University, P.O. Box 531, S-751 21 Uppsala, Sweden.
Abstract:
Amperometric detection at a naked platinum microelectrode is shown to be compatible with pressure-programmed packed capillary column supercritical fluid chromatography (SFC) using carbon dioxide modified with as little as 1% acetonitrile. Amperometric detection in modified carbon dioxide is, hence, possible without addition of salts, which otherwise may limit the stability of the chromatographic system. The detection, which can been based on either oxidations or reductions, is also compatible with the use of methanol as a sole modifier. Picogram amounts of ferrocene could be detected after separations both at a constant pressure and under pressure-programmed conditions. The detection limit for ferrocene, at a constant pressure of 200 atm, was found to be approximately 20 pg. The response of the amperometric detector was observed to increase with decreased mobile phase density and increased amount of added modifier. The injection of increasing amounts of analytes resulted in increased peak tailing, most likely due to the limited solubility of the oxidation products in the mobile phase. The influence of this effect was, however, small for the amounts of analytes relevent in capillary column SFC.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...