Chiral discrimination in the gas phase using different transducers: thickness shear mode resonators and

K Bodenhöfer1, A Hierlemann, J Seemann

  • 1Center of Interface Analysis and Sensors, and Institute of Physical and Theoretical Chemistry, Institute of Organic Chemistry, University of Tübingen, Auf der Morgenstelle 8, D-72076 Tübingen, Germany.

Related Concept Videos

Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons00:58

¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons

Replacing each alpha-hydrogen in chloroethane by bromine (or a different functional group) yields a pair of enantiomers. Such protons are called prochiral or enantiotopic and are related by a mirror plane. Enantiotopic protons are chemically equivalent in an achiral environment. Because most proton NMR spectra are recorded using achiral solvents, enantiotopic hydrogens yield a single signal.
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Chirality at Nitrogen, Phosphorus, and Sulfur02:30

Chirality at Nitrogen, Phosphorus, and Sulfur

Chirality is most prevalent in carbon-based tetrahedral compounds, but this important facet of molecular symmetry extends to sp3-hybridized nitrogen, phosphorus and sulfur centers, including trivalent molecules with lone pairs. Here, the lone pair behaves as a functional group in addition to the other three substituents to form an analogous tetrahedral center that can be chiral.
A consequence of chirality is the need for enantiomeric resolution. While this is theoretically possible for all...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...