Weighted least-squares approach to calculating limits of detection and quantification by modeling variability as a

M E Zorn1, R D Gibbons, W C Sonzogni

  • 1Water Chemistry Program, University of Wisconsin [Formula: see text] Madison, Madison, Wisconsin 53706, and Department of Biostatistics, University of Illinois [Formula: see text] Chicago, Chicago, Illinois 60612.

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Mechanistic Models: Compartment Models in Individual and Population Analysis01:23

Mechanistic Models: Compartment Models in Individual and Population Analysis

Mechanistic models are utilized in individual analysis using single-source data, but imperfections arise due to data collection errors, preventing perfect prediction of observed data. The mathematical equation involves known values (Xi), observed concentrations (Ci), measurement errors (εi), model parameters (ϕj), and the related function (ƒi) for i number of values. Different least-squares metrics quantify differences between predicted and observed values. The ordinary least squares (OLS)...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis00:59

Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis

Noncompartmental analyses offer an alternative method for describing drug pharmacokinetics without relying on a specific compartmental model. In this approach, the drug's pharmacokinetics are assumed to be linear, with the terminal phase log-linear. This assumption allows for simplified analysis and interpretation of the drug's behavior in the body.
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...
Pharmacodynamic Models: Linear Concentration–Effect Model01:15

Pharmacodynamic Models: Linear Concentration–Effect Model

The linear concentration–effect model, underpinned by the principle that pharmacological effect (E) is directly proportional to plasma drug concentration (C), emerges as a pivotal simplification of the Emax model for conditions where C is significantly less than EC50. This model portrays a linear trajectory of the concentration–effect relationship when drug levels are markedly below the EC50 threshold.Despite its inherent assumption of continuous effect augmentation with increasing drug...