Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Environmental applications of gas chromatography/atomic emission detection
1National Exposure Research Laboratory, Characterization Research Division, U.S. Environmental Protection Agency, P.O. Box 93478, Las Vegas, Nevada 89193-3478.
Abstract:
A gas chromatograph/atomic emission detector (GC/AED) system has been evaluated for its applicability to environmental analysis. Detection limits, elemental response factors, and regression analysis data were determined for 58 semivolatile environmental contaminants. Detection limits for injected analytes ranged from 0.17 to 3.0 ng on the hydrogen 486-nm channel, from 1.0 to 5.0 ng on the nitrogen 174-nm channel, from 0.65 to 11.7 ng on the oxygen 777-nm channel, from 0.071 to 3.0 ng on the chlorine 479-nm channel, and from 0.023 to 0.038 ng on the sulfur 181-nm channel. Mean elemental response factors (ERFs) measured on these channels, relative to the carbon 496-nm channel, were hydrogen, 0.084 (mean %RSD = 6.6); nitrogen, 0.246 (mean %RSD = 19); oxygen, 0.459 (mean %RSD = 16); and chlorine, 0.417 (mean %RSD = 3.6). The higher precision obtained for hydrogen and chlorine, relative to that for nitrogen and oxygen, is attributed to the ability to scan these elemental channels in the same GC run as the carbon 496-nm channel (diode array wavelength range limitation of ∼40 nm/run). Mean ERFs of standard compounds were used to determine the molecular formulas of chlorinated hydrocarbons and chlorinated organosulfur compounds in a contaminated environmental soil sample. These formulas are in good agreement with the molecular weights and chlorine isotopic data obtained from low-resolution gas chromatography/mass spectrometry.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Atomic Emission Spectroscopy: Instrumentation