Related Experiment Video
Updated: Jun 1, 2026

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Sterile radial artery granuloma after transradial cardiac catheterization
Christian Zellner1, Yerem Yeghiazarians1, Thomas A Ports1
1Division of Cardiology, Department of Medicine, University of California San Francisco, San Francisco, CA, USA.
Abstract:
Transradial cardiac catheterization has lower rates of arterial access site complications than transfemoral procedures. However, there are complications that are unique to the transradial route. We present the case of a sterile granuloma occurring at the site of radial arterial access as a reaction to the hydrophilic coating on the sheath. The clinical presentation was suggestive of an infected pseudoaneurysm. Awareness of this entity may help clinicians avoid unnecessary surgical procedures, as these granulomata are transient self-limiting reactions.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Peripheral Artery Disease III: Interprofessional Care