Related Experiment Video
Updated: Jun 1, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Simple automated generation of gradient elution conditions in sequential injection chromatography using monolithic
Petra Koblová1, Hana Sklenářová, Petr Chocholouš
1Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 50005 Hradec Králové, Czech Republic.
This study introduces automated gradient profile creation for gradient-elution sequential injection chromatography (GE-SIC). The method efficiently separates indomethacin and its degradation products, offering comparable performance to HPLC.
Area of Science:
- Analytical Chemistry
- Chromatography
- Pharmaceutical Analysis
Background:
- Sequential Injection Chromatography (SIC) offers advantages in automation and reduced solvent consumption.
- Developing gradient elution profiles in SIC can enhance separation efficiency for complex mixtures.
- Accurate quantification of active pharmaceutical ingredients and their impurities is crucial for quality control.
Purpose of the Study:
- To demonstrate a simple, automated method for creating gradient profiles in GE-SIC.
- To validate the method for the separation and simultaneous assay of indomethacin and its degradation products.
- To compare the performance of the novel GE-SIC method with conventional High-Performance Liquid Chromatography (HPLC).
Main Methods:
- Utilized a FIAlab(®) 3000 SIC system with a C18 monolithic column.
- Employed automated mixing of acetonitrile and aqueous phosphoric acid to generate gradient elution.
- Incorporated ketoprofen as an internal standard for quantification.
- Optimized mobile phase composition and flow rate (1.2 mL/min) for separation.
Main Results:
- Achieved excellent chromatographic resolution (R > 2.00) for indomethacin, its degradation products, and the internal standard.
- Demonstrated high repeatability of retention times with relative standard deviation (RSD) values between 0.18-0.30%.
- Reported a short net separation time of 3.5 minutes and low mobile phase consumption (4.5 mL per assay).
Conclusions:
- The automated GE-SIC method provides a feasible and efficient approach for pharmaceutical analysis.
- The developed method exhibits figures of merit comparable to conventional HPLC.
- This technique offers a promising alternative for rapid and automated chromatographic separations.
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: