Pituitary microadenomas: diagnosis with two-and three-dimensional MR imaging at 1.5 T before and after injection of

T Stadnik1, A Stevenaert, A Beckers

  • 1Department of Radiology and Medical Imaging, University Hospital Vrije Universiteit Brussel, Belgium.

Radiology
|August 1, 1990
PubMed

Insights

This study evaluated magnetic resonance (MR) imaging sequences for detecting pituitary microadenomas. Coronal T1-weighted SE and 3D FLASH sequences, with or without gadolinium, are recommended for accurate diagnosis.

Area of Science:

  • Radiology
  • Medical Imaging
  • Endocrinology

Background:

  • Pituitary microadenomas require precise imaging for diagnosis.
  • Evaluating the efficacy of various magnetic resonance (MR) imaging sequences is crucial for improving detection rates.

Purpose of the Study:

  • To prospectively assess the diagnostic utility of different MR imaging sequences for detecting pituitary microadenomas.
  • To compare the effectiveness of pre- and post-gadolinium contrast sequences.

Main Methods:

  • Prospective evaluation of 28 patients with surgically confirmed pituitary microadenomas.
  • Utilized coronal and sagittal spin-echo (SE) and three-dimensional fast low-angle shot (3D FLASH) sequences.
  • Compared imaging findings before and after gadolinium injection.

Main Results:

  • Coronal pregadolinium T1-weighted SE and 3D FLASH sequences demonstrated high utility.
  • Combining pre- and post-gadolinium T1-weighted and 3D FLASH sequences yielded 90% true-positive and 5% false-positive findings.
  • Sagittal sequences were deemed useful only in specific cases.

Conclusions:

  • Coronal T1-weighted SE, followed by coronal 3D FLASH (without gadolinium), is advocated for initial diagnosis of pituitary microadenomas.
  • Gadolinium-enhanced sequences should be used if initial diagnosis is uncertain.
  • The choice of MR sequence impacts the accuracy of pituitary microadenoma detection.