Related Experiment Video
Updated: Jun 1, 2026

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Comparison of Potential-Time Waveforms for the Detection of Biogenic Amines in Complex Mixtures following Their
1Department of Chemistry, Iowa State University, Ames, Iowa 50011-3111.
Abstract:
Pulsed amperometric detection (PAD), integrated voltammetric detection (IVD), and integrated square-wave detection (ISWD) at gold electrodes are compared for the flow injection detection of 1,3-diaminopropane in a liquid chromatograph (LC). These detection methods are especially significant for alkylamines and amino acids because (i) the majority of these compounds do not naturally possess chromophoric or fluorophoric functional groups and (ii) their amperometric detection at constant potential at Au electrodes fails because the electrode activity is severely attenuated by the formation of an inert surface oxide (AuO). The anodic response mechanisms for detection of amines require concomitant formation of AuO; therefore, a large background signal is observed with conventional PAD. In comparison, the background is much smaller for IVD and ISWD because the anodic charge for oxide formation (positive scan/step) is compensated by the cathodic charge for oxide reduction (negative scan/step). The limits of detection (S/N = 3) for 1,3-diaminopropane by LC-PAD, LC-IVD and LC-ISWD are about 3 × 10(2) pg (4 pmol), 5 × 10(1) pg (0.7 pmol), and 3 × 10(1) pg (0.5 pmol), respectively, for 25-μL injections. Results are also shown to demonstrate ISWD for detection of nine biogenic amines following their chromatographic separation.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:36Applications of Liquid-Chromatography Tandem Mass Spectrometry in Natural Products Research: Tropane Alkaloids as a Case Study
Published on: March 8, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-II
Mass Spectrometry of Amines
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...