Related Experiment Video
Updated: Jun 1, 2026

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Counterionic Detection by ICP-AES for Determination of Inorganic Anions in Water Elution Ion Chromatography Using a
T Umemura1, R Kitaguchi, H Haraguchi
1Department of Applied Chemistry, School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-01, Japan.
Abstract:
The analytical methods for the determination of inorganic anions by water elution ion chromatography using a zwitterionic column (C14SB-coated column) have been explored, where pure water was used as the mobile phase. In the present ion chromatography, the complicated peaks derived from various "ion pairs" appeared on the chromatogram when the sample solution contained several kinds of cations and anions. The chromatograms with the complicated peaks were simplified by using a preconditioning cation-exchange column. In the preconditioning column, various kinds of countercations of the analyte anions were converted to a particular kind of common cation, and thus all the analyte anions were separated as the common cation form. The more effective separation was achieved by converting to a divalent cation (Mg(2+)) form than a monovalent cation (Na(+)) form, because the anions paired with the divalent cation provided longer elution times than those paired with the monovalent cation. All the analyte anions separated as the common cation form were simply determined from their calibration curves drawn from conductivity detection. In addition, the counterionic determination of the anions was also attempted by using ICP-AES. The analyte anions were determined by measuring their countercations with ICP-AES, where the calibration curve of the countercation measured by ICP-AES could be used.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences