Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Pulsed wave Doppler ultrasonography for the assessment of peripheral vasomotor response in an elderly population
Ke-Vin Chang1, Chueh-Hung Wu, Tyng-Guey Wang
1Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital and National Taiwan University College of Medicine, No. 7, Chun-San S. Rd., Taipei, 100, Taiwan, ROC.
Purpose:
To assess sympathetic vasomotor activity and its changes with age, using pulsed wave Doppler ultrasound.
Methods:
We recruited 20 young adults (24-37 years old) and 20 older individuals (60-81 years old). Pulsed wave Doppler ultrasound was applied over the right radial artery to measure blood flow at rest and after a voluntary inspiratory cough eliciting sympathetic activation. The maximal (Vmax), minimal (Vmin), time-averaged (TAMaxV) blood flow velocity, and the pulsatility index (PI) were calculated and compared between groups.
Results:
At rest, PI was similar in both groups but Vmax and TAMaxV were higher in the older group (p < 0.05). Vmax, Vmin, and TAMaxV decreased, and PI increased after inspiratory cough in both groups (p ≤ 0.001), but this increase was lower in the older group (p < 0.001). TAMaxV after coughing was higher in the older group (p < 0.05). Heart rate did not differ significantly within or between groups.
Conclusions:
The older group exhibited reduced vasomotor reactivity of the radial artery after sympathetic stimulus. Peripheral vasomotor response should be interpreted with caution in elderly populations.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring pulse
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: