Conductometric detection of anions of weak acids in chemically suppressed ion chromatography:  critical point

A Caliamanis1, M J McCormick, P D Carpenter

  • 1Department of Applied Chemistry, Royal Melbourne Institute of Technology, City Campus, GPO Box 2476V Melbourne, Victoria 3001, Australia.

Analytical Chemistry
|June 14, 2011
PubMed

Related Concept Videos

Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations01:29

Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations

In acid-base titrations, conductance measurements are utilized to detect the endpoint. This method is grounded on the fact that electrical conductance relies on the number and mobility of ions. For instance, consider titrating strong acid HCl with a strong NaOH base. Initially, the HCl in the conductivity vessel conducts electricity due to the presence of hydrogen ions and chloride ions. As NaOH is gradually added from the burette, the fast-moving hydrogen ions are replaced by slower-moving...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Conductometric Titrations: Strong Acid-Weak Base and Weak Acid-Strong Base Titrations01:22

Conductometric Titrations: Strong Acid-Weak Base and Weak Acid-Strong Base Titrations

When a weak acid such as acetic acid is titrated against a strong base like sodium hydroxide, the initial conductance is relatively low due to the weak dissociation of acetic acid. However, as sodium hydroxide is added to the solution, it reacts with the acetic acid to produce highly ionized sodium acetate, which causes an increase in conductance. Once all the acetic acid has been neutralized, any additional sodium hydroxide introduces fast-moving hydroxyl ions, leading to a sharper increase in...
Weak Acid Solutions04:02

Weak Acid Solutions

Few compounds act as strong acids. A far greater number of compounds behave as weak acids and only partially react with water, leaving a large majority of dissolved molecules in their original form and generating a relatively small amount of hydronium ions. Weak acids are commonly encountered in nature, being the substances partly responsible for the tangy taste of citrus fruits, the stinging sensation of insect bites, and the unpleasant smells associated with body odor. A familiar example of a...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...