1Dipartimento di Scienze Ambientali, Università Ca' Foscari di Venezia, Dorsoduro 2137, I-30123 Venezia, Italy, Laboratoire de Glaciologie et de Géophysique de l'Environnement du CNRS, 54, rue Molière, Domaine Universitaire, B.P. 96, 38402 Saint Martin d'Hères Cedex, France, and Istituto di Scienze del Mare, Università di Ancona, via Brecce Bianche, I-60131 Ancona, Italy.
Abstract:
The performance of a double-focusing inductively coupled plasma mass spectrometer equipped with a microconcentric nebulizer was investigated for the direct simultaneous determination of Rh, Pd, and Pt in less than 1 mL of melted snow and ice samples originating from remote sites. Ultraclean procedures were adopted in the laboratories and during the pretreatment steps, to avoid possible contamination problems. Spectroscopic and nonspectroscopic interferences affecting the determination of Rh, Pd, and Pt were carefully considered. Detection limits of 0.02, 0.08, and 0.008 pg g(-)(1) for Rh, Pd, and Pt, respectively, were obtained using the following isotopes: (103)Rh, (106)Pd, and (195)Pt. Repeatability of measurements, as RSD, was 27, 28, and 29%, for Rh, Pd, and Pt, respectively. The new method was applied to the analysis of samples coming from Greenland, Antarctica, and the Alps in order to assess the past natural background concentrations and to determine the present level of these polluting substances. The extremely low detection limits allowed the direct analysis of all samples except for two Greenland ice core sections dating from 7260 and 7760 years ago for which a preconcentration step was necessary. Concentration ranges for all snow samples were (in pg g(-)(1)) as follows: Rh (0.0005-0.39), Pd (0.01-16.9), and Pt (0.008-2.7). The lowest concentrations were measured in the enriched Greenland ancient ice samples.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...