A charge coupled device array detector for single-wavelength and multiwavelength ultraviolet absorbance in capillary
E T Bergström1, D M Goodall, B Pokrić
1Department of Chemistry, University of York, York YO10 5DD, UK.
Abstract:
A fundamental limitation to the use of single-point absorbance detection for capillary electrophoresis is irradiance, since it is not possible to create an image at the detection point on capillary that is brighter than the light source. This limitation may be overcome by illuminating a length of the capillary using a fiber-optic bundle and using a charge coupled device (CCD) camera that can image the full length of the illuminated zone. The present paper describes design and development of a CCD detector for UV absorbance that can be used in both multiwavelength and single-wavelength modes. The CCD camera images analyte peaks in the capillary dimension, together with wavelength-resolved absorbance in the dimension perpendicular to the capillary. Successive snapshots of the peaks are added together, after appropriate correction for time-dependent peak displacement, without sacrificing spatial resolution. Measured baseline rms noise values at 200 nm are 34 μAU using a holographic grating in multiwavelength mode and 8 μAU with the addition of a band-pass filter. Both values are in excellent agreement with calculations of limiting shot noise. Performance in multiwavelength mode is constrained by the 470-ms readout time of the CCD used, which sets a maximum duty cycle of 2.3%. Noise contributions from source intensity fluctuations are reduced by using a portion of the CCD image to provide a baseline reference signal. With 4-hydroxybenzoate as test analyte, the linear dynamic range in multiwavelength mode is shown to be between 3 and 4 orders of magnitude. High-quality spectra of 2-, 3-, and 4-methylbenzoates are obtained on capillary and used in deconvolution of closely migrating peaks of the 2- and 3-isomers.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
High-Performance Liquid Chromatography: Types of Detectors
UV–Vis Spectrometers