Optimizing Spectroscopic Signal-to-Noise Ratio in Analysis of Data Collected by a Chromatographic/Spectroscopic
1Analytical Research & Development Department, Amgen Inc., One Amgen Center Drive, Thousand Oaks, California 91320.
Abstract:
To get an accurate spectrum across a chromatographic peak when analyzing data collected from a chromatography/spectroscopy experiment such as liquid chromatography/mass spectrometry, it is often necessary to sum or average the spectra collected across the chromatographic peak. A common practice is to sum the spectra collected across the entire duration of the chromatographic peak. However, this practice is not ideal in terms of optimizing the signal-to-noise ratio (S/N) of the sum spectrum. In most instances, the spectral signals may be so weak at the earlier and later ends of the chromatographic peak that summing these spectra into the sum spectrum may decrease its overall S/N. This report describes some simple guidelines and methods to analyze data collected by a chromatography/spectroscopy system to achieve the maximum S/N from the available data. More specifically, to achieve a better S/N when summing spectra within one chromatographic peak, only the spectra whose relative abundance is above 38% should be included. To achieve the maximum possible S/N, a matched filter should be applied to the data before the spectra are summed.
More Related Videos
08:12An Introduction to Processing, Fitting, and Interpreting Transient Absorption Data
Published on: February 16, 2024
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
UV–Vis Spectrometers
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...