Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
A photothermal interferometer for gas-phase ammonia detection
M A Owens1, C C Davis, R R Dickerson
1Chemical Physics Program, University of Maryland, College Park, Maryland 20742.
Abstract:
Detection of gas-phase ammonia is particularly challenging because ambient ammonia concentrations may be less than 1 ppb (molecules of NH(3) per 10(9) molecules of air), ammonia sticks to many materials commonly used to sample air, and particles containing ammonium may interfere with gas-phase measurements. We have built a new and sensitive photothermal interferometer to detect gas-phase ammonia in situ, under typical atmospheric conditions. Ammonia molecules in sampled air absorb infrared radiation from a CO(2) laser at 9.22 μm, with consequent collisional heating, expansion, and refractive index change. This change in refractive index is detected as a phase shift in one arm of a homodyne interferometer. Measurements of vibrational and electrical noise in the interferometer correlate to an instrumental lower limit of detection of 6.6 ppt ammonia in 1 s. The CO(2) laser output is modulated at 1.2 kHz, and the ac signal from the interferometer is measured with a lock-in amplifier. The detector is zeroed by sampling through a H(3)PO(4)-coated denuder tube and is calibrated by dynamic dilution of two permeation tube outputs and by standard addition. Signal gain is insensitive to CO(2) or H(2)O in the sample, and the signal is linear over 5 orders of magnitude. The instrument 2σ precision is 31 ppt when the signal is integrated for 100 s and 250 ppt with a 1-s integration time. The windowless sample cell and inlet is fabricated entirely of glass to minimize sample loss and hysteresis. The instrument response time is demonstrated to be about 1 s.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Overview
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...