Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in
F Franchi1, R Silvestri, L Cubattoli
1Department of Anaesthesia and Intensive Care, University of Siena, Viale Bracci, 1, 53100 Siena, Italy. franchif@unisi.it
Background:
The purpose of this study was to evaluate the reliability of a new uncalibrated pulse contour method, the MostCare, in determining cardiac output (CO) in septic patients.
Methods:
Thirty patients with septic shock admitted to an intensive care unit, receiving a norepinephrine infusion and requiring haemodynamic monitoring with a pulmonary artery catheter, were prospectively enrolled. Thermodilution measurements of CO (ThD-CO) were considered as the 'gold standard'. MostCare was connected to the monitoring system of the radial arterial pressure waveform to obtain a continuous CO calculation (MostCare-CO). ThD-CO and MostCare-CO measurements were recorded at three different haemodynamic states: baseline (T1), after raising mean arterial pressure (MAP) to 90 mm Hg by increasing the norepinephrine infusion (T2), and after returning the MAP to baseline value by decreasing vasopressor therapy (T3). A Bland-Altman and linear regression analyses were performed.
Results:
A total of 90 paired ThD-CO and MostCare-CO measures were obtained (range 4.1-13.9 litre min(-1) for ThD-CO and 4.5-13.5 litre min(-1) for MostCare-CO). A good correlation between ThD-CO and MostCare-CO was observed (R = 0.93). The mean bias between the two techniques was -0.26 litre min(-1) (sd 0.98 litre min(-1)) and the 95% limits of agreement were -2.22 to 1.70 litre min(-1). The percentage of error was 25%. Pearson's R was 0.94, 0.92, and 0.93 at T1, T2, and T3, respectively.
Conclusions:
MostCare-CO and ThD-CO showed a good agreement at each time of the study. The reliability of the MostCare system was not affected by the vascular tone changes produced by a norepinephrine infusion.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...