Characterizing inward leakage in a pressure-demand, self-contained breathing apparatus
1Fire Research Division, Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA. rodney.bryant@nist.gov
Abstract:
An analytical model of the flow across a resistive flow path such as an orifice or pipe was applied to predict the inward leakage in the facepiece of a self-contained breathing apparatus (SCBA) during a steady below-ambient facepiece pressure. The model was used to estimate leakage rates with respect to the size of the leak and for below-ambient (negative) pressure conditions reflective of measured occurrences. Results of the model were also used to make quantitative estimates of the protection level of the respirator. Experiments were designed to induce a continuous below-ambient pressure inside the facepiece of a pressure-demand SCBA mounted on a headform. Negative facepiece pressure measured in the presence of a leak correlated with the measured particle concentration ratio. Results show that the analytical model generated reasonable estimates of leakage rates during conditions of negative pressure inside the facepiece. Thus, the analytical model performed well for constant flow conditions, demonstrating the capability to predict a momentary compromise in respirator protection during momentary negative facepiece pressure conditions.
Related Concept Videos
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulmonary Cycle: Exhalation